Standard Model Shower Timer

$310.00

All products use Watermark Approved Components.

This Standard Model Shower Timer model is recommended for use where vandalism is possible, for instance at caravan parks or tourist hot spots, hostels, hotels or boarding schools. We recommend the commercial standard shower timer model if it is possible (and desired) to access the water pipes.

If you need bulk orders (that is, more than 2 units), please Contact Us to discuss commercial discounts that we can offer. The cost of postage is included in the sale price.

We include the cost of postage with all purchases of our range of shower timers.

Description

Operation of Standard Model Shower Timer

NOTE: There is no internal functional difference between the Residential (grey) and the Commercial (blue) Models. It is just the look and feel of the face plate that is different.

What’s Included In Your Purchase ?

  • The Standard Model Shower Timer unit also comes with a 12 Volt power pack and solenoid valve for use in Australia.
  • Printed instruction manual

How it Works

  • The shower is terminated after a pre-determined time and that is followed by a “discouraging” waiting period during which the shower will not operate
  • The shower and waiting time are pre programmed by the owner from 0-12 mins
  • The shower is terminated after a pre-determined time and that is followed by a “discouraging” waiting period during which the shower will not operate
  • The heavy duty shower timer is best located within the shower area at around eye level for audible and visual efficiency
  • There is a visual display which counts down the minutes and seconds remaining, and is supported by an audible beeper
  • Power is supplied by a 12 Volt power pack that is installed in the roof cavity or away from the unit in an adjoining room

Installation

  • The unit is connected via  12 Volt power pack (supplied) that requires a 240 Volt power outlet
  • Assemble and fit the shower timer as per the assembly instructions in the kit
  • For more efficient water utilisation during showers, consider installing a water saving shower head (around 9 L / minute)

Programming

  • Both shower time and waiting time are selected and set by the owner from a number of pre-programmed time options
  • The SHOWER TIME can be selected in whole minutes up to 12 minutes
  • The WAIT TIME can be selected between showers from 0, 15, 30, 60, 120 or 300 seconds
  • The settings can only be changed by first removing the power source
  • Power failure will not change the settings
  • In the normal condition the settings can be seen at a glance because the visual display indicates the two settings alternately for three seconds each
  • The SHOWER TIME setting is displayed as a steady glow and the WAIT TIME flashes

Operation

  • Press the Start button momentarily to begin the shower time sequence. This will be confirmed by a beep from the buzzer.
  • Hot and cold water taps still control the temperature and water flow, like you would normally use
  • The visual display indicates the remaining shower time in minutes.
  • At each minute change, the buzzer beeps once.
  • From 99 seconds, the display indicates remaining seconds.
  • At each of 30, 20, 10, 5, 4, 3, 2 and 1 seconds remaining, the buzzer beeps once.
  • The water is then cut off and the flashing visual display indicates the remaining Waiting time.
  • Pressing the button at any time during the SHOWER TIME or WAIT TIME has no effect.

Progress Monitoring

  • Visual progress monitoring is provided by displaying the remaining time in minutes and seconds
  • This is supported by audible signals from an electronic buzzer
  • The audible signals indicate increasing urgency until the timer ultimately shuts off the water supply to the shower
  • The waiting time period then commences and is reported by the visual display
  • The visual and audible signals are similar to that used in a microwave oven

Important Note: The shower head is not supplied.

Troubleshooting

Screen blank

Check that 12 Volt power is reaching the circuit board. No display when power is connected suggests reversed polarity. Remove the plug from the socket on the circuit board, remove the back of that plug from the 2 pin socket on the end of the lead and reverse it. The centre of this plug should be positive with respect to the sleeve of the plug.

Beeper screaming

The Start button is extremely sensitive and any distortion of the polycarbonate box can cause the button to activate which puts the timer in Programming mode after 10 seconds. About 10 seconds after that, the beeper will “scream” continuously.

If that happens :

  • Loosen each of the three screws that secure the box to the wall by one turn and test again.
  • If that does not rectify the problem, remove the box from the wall and check the terminal block where the wires to the solenoid valve are connected. Remove the screw that secures that block to the box and test the unit with the block hanging free.
  • If the symptoms persist, the solution is to fit hard plastic shims (200 micron) under each of the four mounting points of the electronic circuit board. We can supply these free of charge by express post if required or you can return the unit for warranty claim.

Cold water feeding back into hot system

If there is significant difference in pressure between hot and cold water, this can be a problem when the user leaves hot and cold taps turned on after the shower is finished.

That can cause back flow when there are multiple showers and the hot water is cooled by the cold coming from those open taps.

  • One solution is to fit a one way valve in the hot feed to the shower.
  • Another is to fit the solenoid valve in the hot feed pipe only rather than after mixing.
  • Thirdly, you can order our standard (heavy duty) model which will drive two solenoid valves, one in hot and one in cold feed pipes. The heavy duty Power Pack will also be necessary.
  • Standard model shower timer-commercial
    Select options This product has multiple variants. The options may be chosen on the product page

    Standard Model Shower Timer

    $310.00
  • PIN Model Shower Timer

    $275.00
  • Heavy Duty Model Shower Timer

    $435.00
  • Economy Model Shower Timer

    $255.00
  • Battery Model Shower Timer (DIY)

    $285.00

Additional information

Type

Residential, Commercial